Crest Cryogenic Repository System (-190°C)

Crest Cryogenic Storage System (-190°C)

Crest is a liquid nitrogen cryogenic storage system that combines ergonomic design, advanced insulation, and intelligent monitoring to ensure secure, efficient, and reliable long-term biospecimen preservation.
Read More +
Samplock Ultra-Low Temperature Freezer (-80°C)

Samplock Ultra-Low Temperature Freezer (-80°C)

Samplock features digital sample management, intuitive navigation, and high-density storage to improve laboratory efficiency while protecting valuable biospecimens.
Read More +

What Should You Consider When Choosing a LN2 or ULT Freezer?

What Should You Consider When Choosing a LN2 or ULT Freezer?

LN2 or ULT freezers are widely used for long-term biospecimen storage. The right choice should balance capacity, space utilization, temperature stability, usability, and emergency preparedness. Start by estimating current inventory and future growth to determine the required capacity and avoid either overcrowding or underused space. Key technical considerations include temperature uniformity, insulation performance, monitoring, and alarm functions.


Daily workflow matters as well. For frequent access, features such as ergonomic handling, clear sample location, and convenient liquid nitrogen management can improve efficiency. Genepoint’s Crest cryogenic storage systems combine ergonomic design with intelligent temperature and liquid-level monitoring for dependable routine operation. For -80°C storage, Samplock integrates high-density shelving, LED-guided navigation, and digital sample management to help users locate specimens quickly.


Also consider how samples will be protected during power outages or equipment failures, including emergency transfer procedures. A sound selection should therefore address not only capacity and temperature, but also sample integrity, operating efficiency, data management, and long-term serviceability.


What Should You Consider When Choosing a LN2 or ULT Freezer?
How Can You Reduce Liquid Nitrogen Consumption?

How Can You Reduce Liquid Nitrogen Consumption?

Liquid nitrogen loss is inevitable during long-term storage, but efficient equipment design and operating practices can significantly reduce unnecessary consumption and operating costs.


Insulation performance is the first consideration. Genepoint’s Crest cryogenic storage system combines double-layer vacuum insulation with a narrow-neck design to limit heat ingress and reduce evaporation while maintaining a stable cryogenic environment. Daily handling also affects consumption. Crest’s vapor-phase design helps minimize temperature fluctuations during replenishment and sample access, while its fog-control function avoids using additional liquid nitrogen during lid opening. Planning sample access and monitoring liquid levels and equipment status can further reduce avoidable losses.


When evaluating lifecycle cost, look beyond the purchase price. Insulation, structural design, operating practices, and routine liquid nitrogen consumption all influence the true cost of cryogenic storage.

Contact Us to Empower Your Automated Sample Storage